The interconnecting strips enable more MCB´s, switches and protective switches to be interconnected between each other. With the interconnection of our current protective switches BONEGA®EV-6P with the MCB´s BONEGA® P-E-P or BONEGA®EV-6J, you can assemble an associated electrical device which is always cheaper than the compact devices with the same function. We supply the copper 1, 2, 3, 4-pole interconnecting “reed” strips with insulation, and the 1-pole and 3-pole forked types.
The insulation is made of ABS see Comparison of ABS, the self-extinguishing ABS VO and PVC (in )
The strips are supplied either with the cross-sections of 16 mm2 or 10 mm2, always with insulating material made of self-extinguishing ABS-VO. The copper contacts (reeds) are located closed at the strip edges. See our offer of MCB´s accessories.
The single-pole MCB´s can be interconnected also in the so-called “German” way, i.e. with a special strip without any insulation. When accepting this method, it is necessary to break off both barriers against the inter-phase short-circuit (see protection against an inter-phase short-circuit).
Technical Data |
|
Number of poles: | 1,2,3,4 |
Supplied length: | 1 m |
Load current: | 80 A |
Material of the strip: | Copper (E-CU - F25) |
Material of insulation: | Self-extinguishing ABS - VO (PC/ABS -Biend UL 94 - VO) |
Compliance with the standards: | DIN EN 60 439-1: 1994 a VDE 0660, part 500 |
Short-circuit resistance: | 25 kA |
Strip cross-section: | 16 mm2 |
Dimensions of a reed: | 4 x 12 mm |
Insulation resistance: | 36kV/ mm |
Mechanical resistance of the insulation pursuant to the standard : |
IEC 68 -2 |
Rated voltage: | 415 V |
Operative voltage: | max. 500 V |
Max. load: | 4 kV |
Parameters of the interconnecting strip ampere load |
|||||||||||
1 phase /two interconnected strips | 2,3 and 4 phase / two interconnected strips | ||||||||||
Interconnecting strip’s cross-section in mm2 |
10 | 12 | 16 | 20 | 25 | 36 | 10 | 16 | 25 | 36 | |
Power supply from the strip’s edge, max. current Is = A |
63/ 126 |
65/ 130 |
80/ 160 |
90/ 180 |
100/ 200 |
130/ 260 |
63/ 126 |
80/ 160 |
100/ 200 |
130/ 260 |
|
Power supply in the middle of the strip Max. current Is = A |
|
100/ 200 |
110/ 220 |
130/ 260 |
150/ 300 |
180/ 360 |
220/ 440 |
100/ 200 |
130/ 260 |
180/ 360 |
220/ 440 |
|
Single-pole copper interconnecting strip with contacts at the strip’s edge
There are 57 contacts on the length of 1 m. |
|||||||||||||||
|
Two-pole copper interconnecting strip with contacts at the strip’s edge
There are 56 contacts on the length of 1 m. |
|||||||||||||||
|
3-pole copper interconnecting strip with contacts at the strip’s edge
There are 54 contacts on the length of 1 m. |
|||||||||||||||
|
4-pole copper interconnecting strip with contacts at the strip’s edge
There are 56 contacts on the length of 1 m. |
|||||||||||||||
Plastic strip terminal head for 2 and 3- pole stripsCode of Order: 08 - 1011
|
|
Single-pole copper interconnecting strip with contacts at the strip’s edge
There are 55 contacts on the length of 1 m. |
|||||||||||||||
|
3-pole copper interconnecting strip with contacts at the strip’s edge
There are 54 contacts on the length of 1 m. |
|||||||||||||||
|
||||||||||||||||
Plastic strip terminal head for 3- pole stripsCode of Order: 08 - 0011
|
Export Manager: Michal Hudeček, tel: +420 605 518 724, [email protected]
Sales Department: - Mrs Adriana Jamná, fax +420 518 335 216, email : [email protected], 696 66 Sudoměřice nad Moravou 302
|
Products | About us | Customer support | Become our partner | Certificates & declarations | Contacts | Site map |
, Potoční 302, 696 66 Sudoměřice nad Moravou, Czech Republic, [email protected], tel. +420 605 518 724 |